Ashirvad Flowguard Plus End Cap
Ashirvad Flowguard Plus End Cap
ಉಪಲಬ್ದವಿದೆ
ಪಿಕಪ್ ಲಭ್ಯತೆಯನ್ನು ಲೋಡ್ ಮಾಡಲು ಸಾಧ್ಯವಾಗಲಿಲ್ಲ
Product Highlights
Quick Answer: What is Ashirvad Flowguard Plus End Cap used for?
Ashirvad Flowguard Plus End Cap is a pipe termination fitting for sealing the end of CPVC pipes, designed for closing off unused pipe ends and dead-end branches in hot and cold water systems with permanent solvent weld sealing.
- Material: CPVC (Chlorinated Polyvinyl Chloride)
- Function: Pipe end termination and sealing
- Temperature Rating: Up to 93°C (200°F)
- Pressure Rating: SDR-11 (PN 15 / 15 kg/cm²)
- Connection: Socket type (Solvent Weld)
Product Description
Ashirvad Flowguard Plus End Cap provides a permanent, leak-proof seal for terminating CPVC pipe ends. This essential fitting is used to close off unused branches, dead-end lines, or temporary pipe terminations during phased construction. The precision-molded socket design ensures proper pipe insertion depth and optimal solvent cement bonding for a watertight seal that withstands full system pressure.
Manufactured from high-grade CPVC compound, this end cap maintains the same temperature and pressure ratings as the pipe system. The smooth exterior finish allows for easy installation in tight spaces, while the durable construction ensures long-term reliability. Essential for system testing, future expansion provisions, and closing off abandoned pipe sections during renovations.
Technical Specifications (Quick Reference)
| Specification | Details |
|---|---|
| Fitting Type | End Cap (Pipe Termination) |
| Material | CPVC (Chlorinated Polyvinyl Chloride) |
| Maximum Temperature | 93°C (200°F) continuous service |
| Pressure Rating | SDR-11 (PN 15 / 15 kg/cm² at 25°C) |
| Connection Type | Socket (Solvent Weld) |
| Standards | ASTM D2846, NSF certified for potable water |
Recommended Applications
- Dead-End Branches: Sealing unused tee or manifold outlets for future expansion
- System Testing: Temporarily capping pipes during pressure testing before final connections
- Phased Construction: Closing off pipe stubs for future bathroom or kitchen additions
- Renovation Projects: Sealing abandoned pipe sections when rerouting plumbing
- Manifold Systems: Capping unused outlets on distribution manifolds
- Temporary Terminations: Closing pipes during staged installation or repairs
Installation Guidelines
- Pipe Preparation: Cut pipe squarely; deburr and chamfer pipe end at 10-15° angle
- Dry Fit Check: Insert pipe into end cap socket to verify proper fit (pipe should insert 2/3 of socket depth)
- Surface Cleaning: Clean pipe end and cap socket interior with CPVC cleaner
- Solvent Cement Application: Apply Ashirvad CPVC solvent cement evenly to both surfaces; insert pipe with quarter turn and hold for 30 seconds
- Curing & Testing: Allow 24 hours curing before pressure testing; verify no leaks at cap joint
FAQs
1) Can I remove an end cap later if I need to extend the pipe?
No, solvent-welded end caps create permanent joints that cannot be disassembled. To extend a capped pipe, you must cut off the end cap and a short section of pipe, then install a coupler or fitting to continue the line. For temporary closures that may need future access, consider using a threaded plug with a threaded adapter instead.
2) What's the difference between an end cap and a plug?
An end cap is a socket fitting that slides over the outside of a pipe and is solvent-welded in place. A plug is a threaded fitting that screws into a female threaded adapter and can be removed and reinstalled. Use end caps for permanent terminations and plugs for access points or temporary closures.
3) Can I use an end cap for pressure testing a new installation?
Yes, end caps are ideal for pressure testing new CPVC installations. Install end caps on all open pipe ends, allow proper curing time (24 hours), then pressurize the system to 1.5x working pressure for 30 minutes. The caps will hold full system pressure without leaking when properly installed.
4) What sizes are available in CPVC end caps?
Ashirvad Flowguard Plus end caps are available in standard sizes including 15mm (1/2"), 20mm (3/4"), 25mm (1"), 32mm (1-1/4"), and larger diameters. Always match the end cap size to your pipe diameter for proper fit and sealing.
5) Do I need to use solvent cement on end caps?
Yes, always use CPVC solvent cement when installing end caps. The cement creates a molecular fusion between the cap and pipe, forming a permanent, pressure-tight seal. Never install end caps dry or with just primer, as this will result in leaks under pressure.
Why Buy from HomeRun?
- Authentic Ashirvad Hardware: Verified genuine products
- Complete Fitting Range: All termination and closure fittings for system completion
- Bangalore Fulfilment: Quick local availability
Returns & Exchange Policy
- Return within 72 hours of delivery for:
- Damaged or defective product
- Wrong or missing item
- Product cannot be returned once installed or used
- Refer to Refund Policy for complete details