ಉತ್ಪನ್ನ ಮಾಹಿತಿಗೆ ತೆರಳಿ
1 2

Polycab Maxima+ Green Wire HR FR-LSH LF

Polycab Maxima+ Green Wire HR FR-LSH LF

ಉಪಲಬ್ದವಿದೆ

ನಿಯಮಿತ ಬೆಲೆ Rs. 2,074.00
ನಿಯಮಿತ ಬೆಲೆ Rs. 3,195.00 ಮಾರಾಟ ಬೆಲೆ Rs. 2,074.00
ಮಾರಾಟ ಮಾರಾಟವಾಗಿದೆ
Incl GST ಚೆಕ್ಔಟ್ನಲ್ಲಿ ಶಿಪ್ಪಿಂಗ್ ಅನ್ನು ಲೆಕ್ಕಹಾಕಲಾಗುತ್ತದೆ.
Coil Size
Wire Thickness
Colour

Product Highlights

  • Manufacturer: Polycab
  • Product: Maxima+ Green Wire HR FR-LSH LF
  • Series: Maxima+ Green (Premium)
  • Type: Heat Resistant, Flame Retardant, Low Smoke, Halogen-Free, Lead-Free Electrical Wire
  • Application: Premium residential and commercial wiring
  • Environmental: Lead-free eco-friendly formulation

Product Description

Polycab Maxima+ Green Wire (HR FR-LSH LF) is a premium electrical wire combining five safety and environmental properties in one product: Heat Resistant (HR) - handles higher temperatures without insulation degradation; Flame Retardant (FR) - resists fire spread; Low Smoke Halogen-Free (LSH) - emits minimal toxic fumes in a fire, improving evacuation safety; and Lead-Free (LF) - eliminates toxic lead from the insulation for environmental compliance. Together these make it the correct specification for premium residential fitouts, commercial buildings, high-rise constructions, and green building certified projects where standard wires do not meet the required safety or environmental standard.

The lead-free formulation is particularly relevant for green building certifications and projects where environmental compliance is a requirement. The low smoke halogen-free property is critical for high-rise and commercial buildings where smoke toxicity during a fire event directly affects occupant evacuation. Suitable for all standard residential and commercial wiring applications - conduit, surface, and concealed installation.

Technical Specifications

Technical Specifications (Quick Reference)

Specification Details
Brand Polycab
Series Maxima+ Green (Premium)
Product Type Heat Resistant FR-LSH Lead-Free Electrical Wire
HR Heat Resistant - withstands higher temperatures without insulation degradation
FR Flame Retardant - resists fire spread along the wire
LSH Low Smoke Halogen-Free - minimal toxic fumes in fire, improves evacuation safety
LF Lead-Free - eco-friendly formulation, suitable for green building certifications

Polycab Product Authentication Guide

Verify your genuine Polycab product in 3 steps

  1. Locate the code: Find the unique text code and QR label printed on the product box.
  2. Send a text: Message the unique code to 99010 00025.
  3. Receive confirmation: A genuine product will receive a reply from BG-PRDSEC-S confirming the specific product details - e.g. "Polycab authenticates genuine pack of PVC Ins. Ind. Cables..."
  • Resending the same code will return: "The code has already been scanned 1 times"
  • Counterfeit products will return an INVALID code error message
  • If the QR code is blurry or too small, always verify via SMS instead

Recommended Applications

Where Polycab Maxima+ Green fits best

  • Premium residential wiring: High-end homes and luxury apartments where enhanced safety standards are specified
  • High-rise buildings: The LSH property reduces toxic smoke in fire events - critical for safe evacuation in multi-storey buildings
  • Commercial and office buildings: Offices, retail spaces, and commercial establishments requiring fire safety compliance
  • Green building projects: Lead-free formulation supports LEED, IGBC, and other green building certification requirements
  • High-temperature areas: Locations near heat sources, industrial areas, and roof spaces where standard wire insulation degrades faster

Why Buy from HomeRun?

  • Authentic Polycab Product: Verified genuine product from authorized distributors
  • Verifiable Authenticity: Each box carries a unique code - verify directly with Polycab via SMS before use
  • Bangalore Fulfilment: Quick local availability with express delivery

FAQs

1) What does HR FR-LSH LF mean on the wire?

HR = Heat Resistant, FR = Flame Retardant, LSH = Low Smoke Halogen-Free, LF = Lead-Free. Each property addresses a specific safety or environmental concern - heat resistance for high-temperature tolerance, flame retardancy for fire spread prevention, low smoke halogen-free for safer evacuation in a fire, and lead-free for environmental compliance. Together they make this wire the correct specification for premium and safety-critical installations.

2) Why does the LSH (Low Smoke Halogen-Free) property matter?

In a fire, standard PVC wire insulation burns and releases thick black smoke and toxic halogen gases that cause rapid loss of visibility and respiratory incapacitation - the leading cause of fire fatalities in enclosed buildings. LSH wire emits significantly less smoke and no halogen gases when burning, giving occupants more time to evacuate and reducing injury from toxic inhalation. This is the reason LSH wire is specified for high-rise buildings, hospitals, schools, and any building where large numbers of people need to evacuate quickly.

3) How do I verify this is genuine Polycab Maxima+ Green wire?

Find the unique code on the product box and SMS it to 99010 00025. A genuine product will receive a confirmation reply from BG-PRDSEC-S with the specific product details. Counterfeit products return an INVALID code error. If the QR code on the box is blurry, use the SMS method. Each code can only be verified once - if you receive a "already scanned" message on a new box, treat it with caution.

4) Is Maxima+ Green suitable for all residential wiring, or only special applications?

It is suitable for all residential wiring applications - the enhanced properties are additional safety margins over standard wire, not limitations on where it can be used. It can replace standard FR wire in any residential circuit. The premium features are most relevant for high-rise apartments, green-certified homes, and areas near heat sources - but there is no application where its enhanced properties are a disadvantage.

5) Why does lead-free wire matter - does standard wire contain lead?

Yes - conventional PVC wire insulation uses lead-based stabilisers in the compound. Lead is a toxic heavy metal that poses environmental hazards during manufacture, installation, and disposal. Lead-free wire eliminates this from the insulation compound, making it safer to handle, dispose of, and suitable for green building certifications (LEED, IGBC) that restrict the use of hazardous materials in building components. For most standard wiring, the practical day-to-day difference is minimal - the benefit is most significant in terms of environmental compliance and long-term material safety.

Returns & Exchange Policy

  1. This product is non-returnable
  2. Replacement available within 24 hours of delivery for:
    • Damaged or defective product
    • Wrong or missing item
  3. Refer to Refund Policy for complete details
ಸಂಪೂರ್ಣ ವಿವರಗಳನ್ನು ವೀಕ್ಷಿಸಿ
0

0 items

Rs. 0.00

View Cart