Ashirvad Flowguard Plus CPVC Threaded Tank Nipple

Ashirvad Flowguard Plus CPVC Threaded Tank Nipple

स्टॉक में

नियमित रूप से मूल्य Rs. 49.00
नियमित रूप से मूल्य Rs. 84.00 विक्रय कीमत Rs. 49.00
बिक्री बिक गया
Including GST शिपिंग की गणना चेकआउट पर की जाएगी।
Size

Product Highlights

Quick Answer: What is Ashirvad Flowguard Plus CPVC Threaded Tank Nipple used for?

Ashirvad Flowguard Plus CPVC Threaded Tank Nipple is a specialized fitting for connecting overhead water tanks to CPVC distribution pipes, designed for creating leak-proof tank outlet connections with threaded flange and CPVC socket construction.

  • Material: CPVC body with threaded flange
  • Function: Tank outlet to pipe connection
  • Temperature Rating: Up to 93°C (200°F)
  • Pressure Rating: PN 15 (15 kg/cm²)
  • Connection: Threaded flange (tank side) + Socket (pipe side)

Product Description

Ashirvad Flowguard Plus CPVC Threaded Tank Nipple provides a reliable connection between overhead water storage tanks and CPVC distribution systems. This specialized fitting features a threaded flange on one end that screws into the tank outlet, and a CPVC socket on the other end for solvent-welding to distribution pipes. The design ensures a watertight seal at the tank connection while maintaining full compatibility with CPVC piping systems.

The robust construction withstands the constant water pressure from overhead tanks, while the corrosion-resistant CPVC material ensures long-term reliability. The threaded flange includes a gasket seating surface for proper sealing against the tank wall. Essential for new tank installations and tank replacement projects, this fitting provides a professional, leak-free connection that eliminates the need for adapters or improvised solutions.

Technical Specifications (Quick Reference)

Specification Details
Fitting Type Threaded Tank Nipple
Material CPVC with threaded flange
Maximum Temperature 93°C (200°F) continuous service
Pressure Rating PN 15 (15 kg/cm² at 25°C)
Connections Threaded flange + Socket (solvent weld)
Standards ASTM D2846, NSF certified

Recommended Applications

  • Overhead Tank Outlets: Primary connection from overhead water storage tanks to distribution systems
  • Tank Replacements: Connecting new tanks to existing CPVC distribution networks
  • Multi-Story Buildings: Tank outlet connections in apartments and commercial buildings
  • Residential Installations: Independent house overhead tank connections
  • Loft Tank Connections: Connecting loft-mounted storage tanks to plumbing systems
  • Backup Water Systems: Secondary tank connections for water storage backup

Installation Guidelines

  1. Tank Preparation: Ensure tank outlet hole matches nipple thread size; clean tank outlet area thoroughly
  2. Gasket Installation: Place rubber gasket on threaded flange; apply PTFE tape to threads (3-4 wraps)
  3. Tank Connection: Insert nipple through tank outlet from inside; hand-tighten lock nut from outside; use wrench for final tightening
  4. Pipe Connection: Cut CPVC pipe squarely; apply solvent cement to pipe and socket; insert pipe with quarter turn
  5. Testing: Allow 24 hours curing; fill tank slowly and check for leaks at both connections

FAQs

1) What size tank nipple do I need for my overhead tank?

Tank nipple size depends on your distribution pipe diameter and tank outlet size. Common sizes are 20mm (3/4") and 25mm (1") for residential tanks. For larger tanks or multi-unit buildings, 32mm (1-1/4") or 40mm (1-1/2") may be required. Match the nipple size to your main distribution pipe diameter.

2) Do I need a gasket with the threaded tank nipple?

Yes, always use a rubber gasket between the tank wall and the threaded flange to create a watertight seal. The gasket compresses when you tighten the lock nut, preventing leaks. Also apply PTFE tape to the threads for additional sealing.

3) Can I use this fitting for tank inlet connections?

While primarily designed for tank outlets, threaded tank nipples can be used for inlet connections as well. However, for inlet applications, ensure the nipple is positioned to prevent turbulence and consider using a float valve assembly for automatic tank filling.

4) How do I prevent leaks at the tank connection?

To prevent leaks: 1) Use a proper rubber gasket, 2) Apply PTFE tape to threads, 3) Tighten lock nut evenly without over-tightening, 4) Ensure tank outlet hole is smooth and free of cracks. Over-tightening can crack the tank wall, so tighten just until snug and leak-free.

5) Can I replace a tank nipple without draining the entire tank?

It's highly recommended to drain the tank before replacing a tank nipple to avoid water damage and ensure proper installation. If you must work with water in the tank, reduce water level below the outlet and have materials ready for quick installation. However, proper installation requires a dry, clean work area.

Why Buy from HomeRun?

  • Authentic Ashirvad Hardware: Verified genuine products
  • Specialized Fittings: Purpose-built tank connections for reliable installations
  • Bangalore Fulfilment: Quick local availability

Returns & Exchange Policy

  1. Return within 72 hours of delivery for:
    • Damaged or defective product
    • Wrong or missing item
  2. Product cannot be returned once installed or used
  3. Refer to Refund Policy for complete details
पूरा विवरण देखें