Legrand Myrius NextGen DP Switch with Indicator, 32A, 2 Module
- Brand: Legrand
- Product: Myrius NextGen DP Switch, 32A with Indicator
- Current Rating: 32A, 240V AC (up to 7,680W)
- Switch Type: Double Pole (DP) – switches off both live and neutral
- Indicator: Built-in light shows when the switch is ON
- Module Size: 2 Module
- Packaging: 01 Nos
- Application: ACs, geysers, ovens, induction cooktops, washing machines and other high-power appliances
Legrand Myrius NextGen DP Switch, 32A is a heavy-duty double pole switch for high-power appliances. Unlike a normal single pole switch, it switches off both the live and neutral wires together, fully isolating the appliance from the supply. A built-in indicator light glows when the switch is ON, so you can see at a glance whether the appliance has power.
Rated at 32A (up to 7,680W at 240V), it is ideal for air conditioners, geysers, ovens, induction cooktops and washing machines in homes and shops. The 2-module size fits your Myrius NextGen switchboard. As a 32A point carries heavy current, it should be wired with 4 sq mm copper cable and installed by a qualified electrician.
Key Features
- Double Pole Isolation: Cuts both live and neutral for safer switching
- 32A Heavy-Duty Rating: Handles high-power appliances up to 7,680W
- ON Indicator: Shows at a glance when the appliance is powered
- Modular Fit: 2-module size for the Myrius NextGen range
Product Specifications Table
Technical Specifications (Quick Reference)
| Specification | Details |
|---|---|
| Brand / Range | Legrand Myrius NextGen |
| Current Rating | 32A |
| Voltage | 240V AC, single phase |
| Maximum Load | Up to 7,680W at 240V |
| Switch Type | Double Pole (DP) with indicator |
| Module Size | 2 Module |
| Recommended Wire | 4 sq mm copper (minimum) |
| Sold Separately | Plate with frame, wall box |
Recommendations & Ideal Use-Cases
Where this fits best
- Air Conditioners: Isolation switch for split and window ACs up to 2 tons
- Water Heaters: Full disconnection for storage and instant geysers
- Kitchen Appliances: Electric ovens, induction cooktops and high-power kitchen equipment
- Washing Machines: Dedicated switch for front-load and top-load machines
- Shops & Offices: High-power display systems and shop equipment
Installation & Safety
Important – Read Before Use
- Power Off: Switch off the main supply and confirm with a voltage tester
- Use the Right Wire: Use at least 4 sq mm copper wire, protected by a suitably rated MCB
- Connect the Wires: Connect the incoming live and neutral to the input terminals and the outgoing wires to the load terminals; tighten all terminals firmly
- Indicator: Connect as per the wiring diagram so it glows when the switch is ON
- Test: Restore power, run the appliance and check the terminals don't heat up; confirm the indicator works
32A circuits carry heavy current – installation by a qualified electrician is strongly recommended.
1) What is the difference between a DP and an SP switch?
A Double Pole (DP) switch cuts both the live and neutral wires, fully isolating the appliance. A Single Pole (SP) switch only cuts the live wire. DP switches are the safer choice for high-power appliances such as ACs and geysers.
2) What does the indicator light show?
It glows when the switch is ON, so you can see at a glance whether the appliance has power – useful for appliances behind cabinets or out of sight. Before any repair work, always confirm the supply is off with a voltage tester; don't rely on the indicator alone.
3) Can I use it for a 1.5-ton AC?
Yes. A 1.5-ton AC typically draws about 10 – 15A while running, well within the 32A rating, which also leaves margin for the higher current when the compressor starts.
4) What wire size should I use?
Use at least 4 sq mm copper wire. For long runs over about 15 m, 6 sq mm helps reduce voltage drop. Always follow local electrical codes and use a licensed electrician.
5) Can it be used for three-phase equipment?
No. It is for 240V single-phase supply only. Three-phase equipment needs a triple pole or four-pole switch rated for three-phase use.
6) Can I use it as the main switch for my home?
No. It is meant for individual appliances. For main isolation of the whole house, use a proper main switch or isolator in your distribution board, rated for your total load.
Why Buy from HomeRun?
- Authentic Legrand Product: Verified genuine product sourced from authorized Legrand channels
- 60-Minute Bangalore Delivery: Express delivery to active service zones
- Complete Range: Plates, switches, sockets and regulators from Myrius NextGen
- Return within 72 hours of delivery for:
- Damaged or defective product
- Wrong or missing item
- Product cannot be returned once installed or used
- Refer to Refund Policy for complete details
You may also like