Racold CDR DLX Horizontal 4-Star Storage Water Heater (Geyser) - 15L
- Brand: Racold
- Model Series: CDR DLX 15-Litre Horizontal Series
- Available Variants: RHS (Right-Hand Side), LHS (Left-Hand Side)
- Storage Capacity: 15 Litres
- Power Consumption: 2000 Watts (2 kW)
- Energy Rating: BEE 4-Star Certified
- Max Pressure Handling: 8 Bars (0.8 MPa)
- Item Dimension (H x W x D): 320 x 570 x 330 mm / 12.6" x 22.4" x 13.0"
- Application: Wall-mounted horizontal water heating for tight bathroom layouts and false-ceiling installations
The Racold CDR DLX 15L Horizontal series is built as a horizontal cylinder measuring 320 mm in Height, 570 mm in Width, and 330 mm in Depth. This configuration is designed specifically to fit under false ceilings and inside tight bathroom layouts. Racold is a well-known Indian water heater brand backed by the global expertise of the Ariston Group.
This series is available in two side-specific variants to match existing bathroom plumbing. The RHS (Right-Hand Side) model locates connection lines on the right, while the LHS (Left-Hand Side) model routes them to the left, simplifying installation without complex external pipe routing. Engineered to handle water pressures up to 8 Bars, it ensures full safety and performance when paired with high-pressure booster pump systems in multi-story high-rise buildings. It combines Titanium Plus Technology (a titanium enamel inner tank coating) with a large Magnesium Anode, protecting the core steel against electrochemical corrosion and scaly mineral buildup.
Technical Specifications
Both child variants share the following technical specifications; only the plumbing connection side differs:
| Feature / Specification Element | Parent Listing / Shared Technical Specifications |
|---|---|
| Model Series Family | Racold CDR DLX 15-Litre Horizontal Series |
| Available Variants | RHS Model (Right Connections) / LHS Model (Left Connections) |
| Article / Model Code | RHS: CDR DLX 15H 2KW WH | LHS: CDR DLX 15HL 2KW WH |
| Storage Capacity Profile | 15 Liters |
| Power Consumption Rate | 2000 Watts (2 kW) |
| BEE Energy Rating Profile | 4-Star Certified Efficiency Layout |
| Maximum Rated Pressure | 8 Bars (0.8 MPa) |
| Inner Tank Material Tech | High-Grade Steel with Titanium Enamel Coating |
| Corrosion Protection Core | Oversized Magnesium Anode Rod |
| Item Dimension (H x W x D) | 320 x 570 x 330 mm / 12.6" x 22.4" x 13.0" |
| Net Appliance Weight | 9.26 Kilograms |
| Tank Structural Warranty | 7 Years Tank Warranty |
| Comprehensive Core Warranty | 2 Years Comprehensive Product Warranty |
Key Features
- Space-Saving Form Factor & Size: Horizontal cylinder configuration designed specifically to fit under false ceilings and inside tight bathroom layouts
- Flexible Piping Configurations (2 Options): Available in RHS (Right-Hand Side) and LHS (Left-Hand Side) variants to match existing bathroom plumbing, simplifying installation without complex external pipe routing
- High-Rise & High-Pressure Application: Engineered to handle water pressures up to 8 Bars, ensuring full safety and performance with high-pressure booster pump systems in multi-story high-rise buildings
- Hard Water Protection Application: Titanium Plus Technology combined with a large Magnesium Anode protects the core steel against electrochemical corrosion and scaly mineral buildup
Technical Recommendations
- Piping Orientation Pre-Selection: Confirm the side of your pre-existing plumbing lines before picking a variant. Select the RHS variant if water inlets emerge from the right side of the wall area; select the LHS variant if they emerge from the left
- False Ceiling Clearance: Maintain a strict physical gap of at least 10 to 15 cm above and around the outer shell during installation inside false ceilings to provide access for maintenance check-ups and clear safety valve deployment
- Power Network Allocation: Requires a dedicated 16-Amp socket tied back to a matching 16A circuit breaker (MCB). Avoid sharing the circuit with other bathroom appliances to prevent overload under the 2000-Watt power pull
- Wet Structural Load: Empty dry mass sits at 9.26 kg. When carrying a full 15-litre water load, the total operating mass scales to roughly 25 kg. Mount the installation brackets exclusively onto solid concrete or reinforced brick structures
Why Buy from HomeRun?
- Authentic Racold Product: Verified genuine product sourced from authorized distributors
- 60-Minute Bangalore Delivery: Express delivery to active service zones for urgent needs
- Project-Friendly Availability: Choose the RHS or LHS variant that matches your existing plumbing
1) Can I adapt an RHS model to connect onto an LHS plumbing line during installation?
No. The internal water flow pipes and heating profiles are factory-aligned to work in their designated structural positions. Altering the directional inputs cross-ways can disrupt the stratified thermal storage layers and drop performance. Choose the specific layout child variant that naturally aligns with your wall infrastructure.
2) Why choose a horizontal model variant over a classic vertical model variant?
Horizontal profiles are engineered specifically for modern architecture with low vertical profiles or integrated false ceilings. A horizontal geyser mounts flat along the upper perimeter wall, letting you tuck the entire structure out of sight inside false ceiling cubbies while maintaining easy side-access for service ports.
3) Are connection pipes packed inside the box for both the RHS and LHS variants?
The retail boxes for both child variants contain the main geyser body, dielectric joints, a multi-functional safety valve, and documentation. The external 45 cm inlet and outlet connection pipes are delivered directly by the brand technician during your scheduled authorized setup appointment.
4) Does the Titanium Plus technology protect the inner tank against borehole or hard water supplies?
Yes. The Titanium Plus enamel coating is fused at high temperatures inside the steel inner wall to form a glassy protective barrier. Working in tandem with the high-capacity Magnesium Anode, it effectively minimizes mineral scaling and structural corrosion under tough hard-water environments.
5) How do I know whether to choose the RHS or LHS variant for my bathroom?
Look at where your existing hot and cold water supply pipes currently emerge from the wall. If they come out on the right side (when facing the wall), choose the RHS variant; if they emerge on the left, choose the LHS variant. This avoids the need for extra pipe rerouting during installation.
- Return within 24 hours of delivery for:
- Damaged or defective product
- Wrong or missing item
- Product cannot be returned once installed or used
- Refer to Refund Policy for complete details
You may also like