Open 8 am to 8 pm all days

HomeRun
icon
Free delivery on your first 5 orders, up to 2% cashback on every order, pay on delivery
43% OFF
Legrand RX³ RCCB Four Pole 100mA (AC Type)
Product
Product
Product
Product
Product
Product
Legrand RX³ RCCB Four Pole 100mA (AC Type)
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Thumbnail
Free Deliveryon orders above ₹500
60 MinsPay on Delivery

Legrand RX³ RCCB Four Pole 100mA (AC Type)

₹5,894
₹3,360
Assured 2% CashbackOn purchases above ₹50,000
Incl GST Shipping calculated at checkout.

Bulk Prices

Legrand RX³ RCCB Four Pole 100mA (AC Type)

No bulk prices available right now.

Ampere
25A
₹3,360
40A
₹3,441
63A
₹4,008

  • Brand: Legrand
  • Product: RX³ RCCB Four Pole (4P) 100mA
  • Available Variants: 25A, 40A, 63A
  • Sensitivity: 100mA Trip Threshold
  • Network Configuration: Three-Phase + Neutral
  • Operating Voltage: 415V AC
  • Compliance: IS 12640

Secure your three-phase electrical distribution systems with the high-performance Legrand RX³ Four Pole Residual Current Circuit Breaker (RCCB). Specifically built to safe-keep balanced or unbalanced three-phase lines plus neutral networks, this protective switch acts as a vigilant monitor against ground faults. Engineered with a 100mA medium trip threshold, it is mathematically optimized to capture structural earth current leakage before it degrades insulation or initiates electrical fire hazards, rendering it indispensable for comprehensive commercial, residential, and light industrial panel designs.

Key Highlights

  • Three-Phase Line Fire Shield: Provides full 100mA leakage protection across all 4 poles, actively eliminating fire risk caused by creeping fault currents or insulation tracking faults
  • Bi-Connect Power Interface: Designed with robust lower terminals that dynamically accommodate traditional distribution wire links alongside industrial fork-style or pin-type supply busbars
  • Monthly Toggle Validation: Employs a quick-response mechanical manual flip switch paired with a front-panel test button (T) to safely evaluate the mechanical linkage health instantly
  • Advanced Finger-Safe Housing: Features an engineered thermoplastic chassis with IP20 guarded terminal screens, preventing accidental user contact with live internal components
  • Unified DIN Rail Mount: Incorporates heavy-duty sliding panel clamps to snap smoothly onto generic 35mm symmetrical mounting rails inside modern distribution boards
  • Standard Industrial Framework: Built, tested, and certified in complete harmony with standard quality guidelines (IS 12640)

Technical Specifications

Feature / Specification 25A Variant 40A Variant 63A Variant
Brand Legrand
Product Range RX³ RCCB
Article Code 4025 23 4025 24 4025 25
Rated Current (Iₙ) 25 A 40 A 63 A
Sensitivity (ΔIₙ) 100 mA
Number of Poles Four Pole (4P)
Operating Voltage 415 V AC
Network Configuration Three-Phase + Neutral
Module Width (17.5mm) 4 Modules (72 mm)
Terminal Protection IP 20

Recommendation & Amperage Selection Guide

Four-pole 100mA installations are critical for balancing multi-phase feeds. Choose your variant capacity based on the collective current limit of the panel:

  • 25A Variant (Article Code: 4025 23): Best for light three-phase household distribution layouts or specialized individual multi-phase motor modules. Applications include small 3-phase residential setups, localized workshop sub-panels, centralized low-draw water pump clusters, and standard multi-room sub-boards
  • 40A Variant (Article Code: 4025 24): Best for mid-tier commercial zones, multi-story duplex spaces, or offices operating synchronized air conditioning lines. Applications include balanced residential main boards, medium commercial showrooms, commercial kitchen lines, and primary machinery control sub-stations
  • 63A Variant (Article Code: 4025 25): Best for heavy-duty incoming service loops or high-load master panel arrays that run complex industrial hardware arrays simultaneously. Applications include entire multi-story buildings, massive commercial retail properties, machining workshops, and main incomer panels requiring robust high-amp load overheads

Why Buy from HomeRun?

  • Authentic Legrand Product: Verified genuine product sourced from authorized distributors
  • 60-Minute Bangalore Delivery: Express delivery to active service zones for urgent needs
  • Project-Friendly Availability: Choose the amperage that matches your three-phase panel's collective load

1) Why do I need a 4-Pole RCCB instead of a 2-Pole model?

A 2-Pole RCCB is restricted to single-phase circuits (one live wire and one neutral). A 4-Pole RCCB is mandatory for handling standard three-phase power systems (three distinct live phases — R, Y, B — alongside a shared Neutral wire), ensuring the current sum across all vectors balances out perfectly to zero during normal operations.

2) What causes a 100mA three-phase RCCB to trip?

The device trips when an asymmetry is detected between the incoming phase currents and the returning neutral line. If a fault causes electricity to escape — such as through worn motor winding insulation or damp underground wiring paths — and that leakage hits or exceeds 100mA, the breaker cuts the line instantly to prevent heat generation and potential electrical fires.

3) Is the Neutral line position restricted to a specific side on this switch?

Yes, following standard Legrand international three-phase layouts, the structural terminal paths locate the Neutral line on the right-hand side of the device block, with clear "N" engravings marked visibly adjacent to the screw terminal arrays.

4) Can I pass a higher gauge wiring system into the contact cages?

The integrated terminal ports easily accept hefty distribution conductors up to 35 mm². If your building layout relies on large aluminum supply links exceeding this specification, it is critical to implement a set of Legrand terminal adaptation clips to guarantee a secure, clean terminal fit.

5) Which amperage variant should I choose for my three-phase panel?

Choose 25A for small 3-phase residential setups and localized workshop sub-panels. Choose 40A for balanced residential main boards, medium commercial showrooms, and commercial kitchen lines. Choose 63A for entire multi-story buildings, large retail properties, and main incomer panels handling heavy industrial loads.

  1. Return within 24 hours of delivery for:
    • Damaged or defective product
    • Wrong or missing item
  2. Product cannot be returned once installed or used
  3. Refer to Refund Policy for complete details
legrand rx3 rccb four pole 100ma three phase earth leakage bangalore electrical

You may also like

6% OFF
Maha Cement 50 kg Portland Pozzolana Cement PPC fly ash based bag, IS 1409 BIS certified, buy online at HomeRun
60 MinsPay on Delivery
Free Deliveryon orders above ₹500
Ultratech PPC Cement, 50 Kg Bag
₹ 450₹ 425
Assured 2% CashbackOn purchases above ₹50,000

Bulk Prices

Ultratech PPC Cement, 50 Kg Bag

  • Buy 10+ at ₹415/unit
  • Buy 30+ at ₹405/unit
  • Buy 50+ at ₹395/unit
4% OFF
Maha PPC Cement, 50 Kg Bag | HomeRun, Bangalore
60 MinsPay on Delivery
Free Deliveryon orders above ₹500
Maha PPC Cement, 50 Kg Bag
₹ 380₹ 365
Assured 2% CashbackOn purchases above ₹50,000

Bulk Prices

Maha PPC Cement, 50 Kg Bag

  • Buy 10+ at ₹355/unit
  • Buy 30+ at ₹350/unit
  • Buy 60+ at ₹340/unit
5% OFF
Priya PPC Cement, 50 Kg Bag I Homerun
60 MinsPay on Delivery
Free Deliveryon orders above ₹500
Priya PPC Cement, 50 Kg Bag
₹ 380₹ 360
Assured 2% CashbackOn purchases above ₹50,000

Bulk Prices

Priya PPC Cement, 50 Kg Bag

  • Buy 10+ at ₹350/unit
  • Buy 30+ at ₹345/unit
  • Buy 60+ at ₹335/unit
7% OFF
Roff T01 NCA Tile Adhesive, Grey, 30 Kg Bag | HomeRun, Bangalore
60 MinsPay on Delivery
Free Deliveryon orders above ₹500
Roff T01 NCA Tile Adhesive, Grey, 30 Kg Bag
₹ 460₹ 430
Assured 2% CashbackOn purchases above ₹50,000

Bulk Prices

Roff T01 NCA Tile Adhesive, Grey, 30 Kg Bag

  • Buy 15+ at ₹420/unit
  • Buy 45+ at ₹410/unit