Schneider Acti9 Residual Current Circuit Breaker, RCCB
Couldn't load pickup availability
Schneider Acti9 Residual Current Circuit Breaker (RCCB) is a safety device manufactured by Schneider Electric, engineered to detect earth leakage current and disconnect power to prevent electric shock and electrical fires. The RCCB monitors current flow and trips when it detects imbalance indicating leakage to earth.
Essential for modern electrical installations, Schneider Acti9 RCCB provides life-saving protection against electric shock in wet areas like bathrooms and kitchens. Available in 2 Pole and 4 Pole configurations with 25A, 40A, and 63A current ratings, all at 30mA sensitivity, the quality Schneider Electric engineering ensures reliable operation for electrical installations in Bangalore requiring mandatory earth leakage protection.
| Poles | Current Rating | Sensitivity | Article Code |
|---|---|---|---|
| 2 Pole | 25A | 30mA | A9N16201 |
| 2 Pole | 40A | 30mA | A9N16204 |
| 2 Pole | 63A | 30mA | A9N16208 |
| 4 Pole | 25A | 30mA | A9N16251 |
| 4 Pole | 40A | 30mA | A9N16254 |
| 4 Pole | 63A | 30mA | A9N16258 |
| Specification | Details |
|---|---|
| Brand | Schneider Electric |
| Product Type | Residual Current Circuit Breaker (RCCB) |
| Network Type | AC (Alternating Current) only |
| Function | Earth leakage detection and protection |
| Available Poles | 2 Pole, 4 Pole |
| Current Ratings | 25A, 40A, 63A |
| Sensitivity | 30mA |
Select 2 Pole for single-phase circuits or 4 Pole for three-phase circuits with neutral protection, then choose the current rating (25A, 40A, or 63A) to match your circuit load. All variants come with the standard 30mA sensitivity for shock protection. Use the Article Code from the table above to order the exact combination.
RCCB (Residual Current Circuit Breaker) detects earth leakage current by monitoring the difference between live and neutral currents. When leakage exceeds the rated sensitivity (typically 30mA), it trips to prevent electric shock.
MCB protects against overload and short circuit, while RCCB protects against earth leakage. Both are required for complete protection — RCCB prevents electric shock, MCB protects circuits from overcurrent.
Yes, RCCB is mandatory for wet areas like bathrooms and kitchens as per Indian electrical regulations. It's essential for preventing fatal electric shocks in areas where water contact is possible.
Frequent tripping indicates earth leakage in your electrical system. This could be due to damaged insulation, faulty appliances, or moisture in wiring. Have a qualified electrician investigate and fix the leakage source.